UPS Backup Calculator Pakistan — How Long Will Your Battery Last?

Tap the things you run during load-shedding — or type your total load directly — then pick your battery. You get your real backup time in hours and minutes, using the honest rule that a lead-acid battery only gives about half its charge.

🌀 Ceiling Fan ~80 W0
💡 LED Bulb ~12 W0
📺 LED TV ~100 W0
💻 Laptop ~65 W0
📶 WiFi Router ~10 W0
🧊 Fridge ~150 W0

Wattages are typical values for common Pakistani appliances — a new DC fan uses less, an old fan more. You can always type the exact total below instead.

⚙️ More options — inverter efficiency

The honest maths: usable power = volts × Ah × usable share × efficiency. A 12V 200Ah lead-acid battery holds 2,400 Wh on paper, but only gives about 1,020 Wh in real life — that is why a 400 W load lasts about 2 hours 33 minutes, not 6 hours. At 24V, enter the Ah of one battery — two of that size are used in series. Two batteries in parallel on 12V? Add their Ah together.

🔋 Estimated Backup Time
—
Usable Battery Power
—
Inverter Size Guide
—

Tap the result to copy it

Backup assumes a healthy, fully charged battery. An old battery, or one that did not fully recharge between two load-shedding spells, will give less.

Ready Answers — 200Ah Battery (12V)

Backup times worked out with this calculator's formula — 85% inverter efficiency. The lead-acid / tubular battery gives 1,020 Wh usable; the lithium gives 1,632 Wh usable:

LoadLead-Acid / TubularLithium
200 W — about 2 fans, lights & router5h 6m8h 10m
400 W — fans, lights, TV & router2h 33m4h 5m
600 W — above + fridge & laptop1h 42m2h 43m

Want longer backup? The only real fixes are a bigger battery, a lithium battery, or a smaller load — switching off one fan adds more time than most people expect.

How It Is Calculated

  1. Total energy = battery volts × battery Ah. A 12V 200Ah battery stores 12 × 200 = 2,400 Wh on paper.
  2. Usable energy = total energy × usable share × inverter efficiency. Lead-acid and tubular batteries should only be drained to about 50%; lithium can safely give about 80%. Inverters lose 10–20% as heat — 85% is the typical middle value.
  3. Backup time = usable Wh ÷ load in watts.

Check it yourself: 12 × 200 × 0.5 × 0.85 = 1,020 Wh usable → at a 400 W load, 1,020 ÷ 400 ≈ 2 hours 33 minutes — not the 6 hours the paper figure suggests.

About Battery Types

How to Use This Calculator

This battery backup time calculator works from the charge you can actually use — not the full number printed on the battery — in five quick steps:

  1. Tap + next to each thing that runs during load-shedding — fans, bulbs, TV, laptop, router, fridge — or type your total load in watts directly if you already know it.
  2. Enter your battery size in Ah (printed on the battery) or use a quick-pick size.
  3. Pick 12V for a single-battery UPS, or 24V if your inverter uses two batteries.
  4. Pick your battery type and inverter efficiency (85% suits most home UPS units).
  5. Read your backup time, the usable watt-hours, and the inverter size your load needs.

Frequently Asked Questions (FAQ)

Why does my UPS give less backup than the calculator shows?

The calculator assumes a healthy, fully charged battery. Real backup drops when the battery is old or sulphated, when it did not fully recharge between two load-shedding spells, or when the actual load is higher than estimated — a fridge, for example, draws extra power each time its compressor starts.

How much usable power is in a 200Ah battery?

A 12V 200Ah battery stores 12 × 200 = 2,400 Wh in total. A lead-acid or tubular battery should only be drained halfway, and the inverter loses about 15%, so the usable power is about 2,400 × 0.5 × 0.85 = 1,020 Wh — enough for a 400 W load for about 2 hours 33 minutes. A lithium battery of the same size gives about 1,632 Wh usable, because 80% of it can be used safely.

Lead-acid, tubular or lithium — which gives more backup?

From the same Ah rating, lithium gives roughly 60% more backup time, because you can safely use about 80% of a lithium battery against only about 50% of a lead-acid or tubular one — and lithium also charges faster between load-shedding spells. It costs much more upfront, but lasts many more years.

Can I run my fridge on a UPS?

Usually yes, if the inverter is big enough. A fridge draws about 150 W while running but needs a short surge of 600–900 W each time the compressor starts, so the inverter must handle that surge. This calculator counts the fridge at 150 W; if your UPS trips when the fridge starts, the inverter — not the battery — is the limit.

Is a 24V system better than 12V?

A 24V system uses two batteries in series, so the bank stores twice the energy of a single 12V battery of the same Ah — and it handles heavy loads (above roughly 1,200–1,500 W) more comfortably, which is why bigger inverters are usually 24V. For a few fans and lights, 12V is fine.

How long will a 200Ah battery last during load-shedding?

On a 12V UPS with a lead-acid / tubular 200Ah battery (about 1,020 Wh usable): about 5 hours 6 minutes at a 200 W load (2 fans, lights and a router), 2 hours 33 minutes at 400 W (fans, lights, TV and router), and 1 hour 42 minutes at 600 W (adding a fridge and laptop). A lithium 200Ah battery lasts about 60% longer — about 8 hours 10 minutes at 200 W. The table above shows the full comparison.

Is this tool free? Does my data go anywhere?

Yes, completely free. All calculations happen inside your own phone or computer — nothing you type is uploaded anywhere.